Three different mechanisms : line source model, commercial program(Temp/W) and filed test were used to analyse the thermal behavior of soil in this study. The results of in-site test were similar to line source model and program, the resulted graph showed log pattern curves. After 3 days of soil heating, the vapor emission was continuous with increased range of temperature whose radius is about 1m. The ground was excavated to examine with naked eyes where about 20cm range from pipe heater was completely sintered. Therefore, the soil heating through pipe in ground could be used to soil improvement successfully. In addition, the vapor caused by soil heating was emitted to upward and the most heat was transferred to horizontal direction.
본 연구에서는 지반의 열적거동을 해석하기 위해 선형열원모델, 상용프로그램(Temp/W) 및 현장 가열실험을 수행하여 지 반의 열적거동을 파악한 후 그 결과를 비교하였다. 현장실험결과, 선형열원모델 방정식과 상용프로그램 해석결과가 유사하였으며 분석 결과, 모든 결과치가 유사한 로그형 거동을 보였다. 가열현장의 경우 지속적인 수증기 배출현상이 발생하였고, 3일간 지속가열 후 온도 증가범위가 가열관의 반경 1m 정도까지 확대되는 것을 확인할 수 있었다. 굴착을 통해 지반가열범위를 육안으로 판단한 결과 심도에 상관없이 직경 20cm 지점까지는 완전 건조 소결된 것으로 나타났으며, 가열이 지반의 말뚝효과를 유발하여 연약지반개 량에 효율적으로 사용될 수 있음을 알 수 있었다. 또한, 지반가열로 인해 발생한 수증기가 상부로만 배출되고, 열이 상대적으로 횡방 향으로 많이 전달되는 것을 현장실험으로도 확인할 수 있었다.